Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
EuroIntervention ; 20(7): e445-e452, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38562068

RESUMO

BACKGROUND: Technological and surgical approaches to carotid artery stenting (CAS) have evolved. Modern randomised controlled trials comparing CAS and carotid endarterectomy (CEA) are limited, and information about updated post-intervention outcomes are mostly from retrospective, small studies. AIMS: This study aims to compare the 30-day outcomes of stroke, transient ischaemic attack (TIA), acute myocardial infarction (AMI) and death with propensity-matched groups of CEA and CAS in asymptomatic and symptomatic patients over a recent study period of new CAS technologies and approaches. METHODS: A retrospective, observational, multicentre analysis was conducted including consecutive symptomatic and asymptomatic patients treated with either primary CEA or CAS for internal carotid artery stenosis, between 2015 and 2022. Patients were propensity score-matched based on comorbidities and assessed according to symptom status. Primary endpoints include composite ipsilateral stroke, TIA, AMI and death within 30 days. Secondary endpoints include technical success and length of hospital stay. RESULTS: From a cohort of 1,110 patients, propensity matching produced 269 distinct treatment pairs (n=538). Most patients were asymptomatic (n=456, 85%). All 6 strokes were minor (CEA=2; CAS=4) and registered among asymptomatic patients. One AMI (CEA) and 1 patient death (CAS) were reported among symptomatic patients. Composite stroke/AMI/death were not significantly different between both types of symptom status and both revascularisation techniques (p=0.44 and p=1, respectively). Technical success was 100%. The length of hospital stay was significantly shorter in asymptomatic patients treated with CAS compared to those treated with CEA (p=0.05), but no difference was registered among symptomatic patients (p=0.32). CONCLUSIONS: Propensity-matched analysis suggests that CAS has similar postprocedural outcomes for stroke, AMI and death at 30 days compared to CEA.


Assuntos
Estenose das Carótidas , Endarterectomia das Carótidas , Ataque Isquêmico Transitório , Infarto do Miocárdio , Acidente Vascular Cerebral , Humanos , Endarterectomia das Carótidas/efeitos adversos , Estenose das Carótidas/cirurgia , Ataque Isquêmico Transitório/etiologia , Estudos Retrospectivos , Pontuação de Propensão , Resultado do Tratamento , Stents , Acidente Vascular Cerebral/etiologia , Infarto do Miocárdio/etiologia , Artérias Carótidas , Fatores de Risco
2.
JACC Cardiovasc Interv ; 17(6): 742-752, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38538170

RESUMO

BACKGROUND: Coronary obstruction (CO) is a potentially life-threatening complication of transcatheter aortic valve replacement (TAVR). Chimney stenting or leaflet laceration with transcatheter electrosurgery (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) are 2 techniques developed to prevent CO. OBJECTIVES: The aim of the present study was to compare periprocedural and 1-year outcomes of chimney and BASILICA in TAVR patients at high risk of CO. METHODS: This multicenter observational registry enrolled consecutive TAVR patients at high risk of CO, undergoing either preventive chimney stenting or BASILICA. Clinical success was defined as successful performance of the chimney or BASILICA technique without clinically relevant ostial CO. The primary endpoint was major adverse cardiovascular events, a composite of death, myocardial infarction, stroke, or unplanned target lesion coronary revascularization at 1 year. RESULTS: A total of 168 patients were included: 71 (42.3%) received chimney stenting, and 97 (57.7%) underwent BASILICA. Patients undergoing BASILICA had higher preprocedural risk of CO, as indicated by lower sinotubular junction height (18.2 ± 4.8 mm vs 14.8 ± 3.4 mm; P < 0.001) and diameter (28.2 ± 4.5 vs 26.8 ± 3.4; P = 0.029). Rates of periprocedural complications were similar between the 2 groups. Clinical success was 97.2% and 96.9% in chimney and BASILICA, respectively (P = 0.92). At 1-year follow-up, the cumulative incidence of major adverse cardiovascular events was 18.7% (95% CI: 11%-30.6%) in the chimney group and 19.9% (95% CI: 12.1%-31.5%) in the BASILICA group (log-rank P = 0.848), whereas chimney was associated with a numerically higher cardiovascular mortality than BASILICA (6.7% vs 1.3%; log-rank P = 0.168). CONCLUSIONS: Chimney stenting and BASILICA effectively prevent TAVR-induced acute CO. Both techniques seem to have comparable acceptable periprocedural and 1-year outcomes.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Lacerações , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Lacerações/complicações , Lacerações/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Oclusão Coronária/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Desenho de Prótese
3.
J Pers Med ; 14(3)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38540992

RESUMO

AIMS: To describe through emblematic images rare but clinically relevant carotid artery stenting complications that occurred at two high-volume centres for carotid artery stenting (CAS). BACKGROUND: CAS is an alternative to carotid endarterectomy (CEA) for the treatment of carotid artery stenosis in patients judged to be at high risk for CEA. CAS complications range between 1 and 9% and are higher in older patients complaining of neurological symptoms at the time of presentation. Besides periprocedural or early-after-procedure stroke, which remains the true Achilles' heel of CAS, other dramatic complications might compromise the clinical outcomes of this procedure. METHODS: Five infrequent complications, out of more than 1000 CAS performed in the years 2016-2021, have been described. RESULTS: Among CAS complications, acute carotid stent thrombosis, rescue retrieval of a disconnected distal cerebral embolic protection device, plaque prolapse after carotid stenting, cerebral hyperperfusion syndrome (CHS), and radial artery long sheath entrapment requiring surgical intervention were found to account for 0.3% of the total number of procedures performed by operators with high CAS volume. CONCLUSIONS: Unusual CAS complications may infrequently occur, even in hands of expert operators. To know how to deal with such complications might help interventionalists to improve CAS performance.

4.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-38506737

RESUMO

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Assuntos
Insuficiência da Valva Aórtica , Bioprótese , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Cateteres , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Valvas Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos
5.
Eur Heart J Cardiovasc Pharmacother ; 10(2): 158-169, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-37960983

RESUMO

AIMS: Randomized controlled trials (RCTs) testing bleeding reduction strategies using antiplatelet treatment regimens (BRATs) in acute coronary syndromes (ACS) have shown promising results, but the generalizability of these findings may be significantly influenced by the ethnicity of the patients enrolled, given that East Asian (EA) patients show different ischaemic-bleeding risk profile compared to non-EA patients. METHODS AND RESULTS: RCTs comparing a BRAT vs. standard 12-month dual antiplatelet therapy (DAPT) in patients with ACS undergoing percutaneous coronary intervention (PCI) were selected. The primary efficacy endpoint was major adverse cardiovascular events (MACE) as defined in each trial and the primary safety endpoint was minor or major bleeding. Twenty-six RCTs testing seven different BRATs were included. The only strategy associated with a trade-off in MACE was 'upfront unguided de-escalation' in the subgroup of non-EAs (risk ratio 1.16, 95% confidence interval 1.09-1.24). All but aspirin monotherapy-based strategies (i.e. 'short and very short DAPT followed by aspirin') were associated with reduced bleeding compared with standard DAPT in both EA and non-EA patients. There were no significant differences between subgroups, but the lack of RCTs in some of the included strategies and the difference in the certainty of evidence between EA and non-EA patients revealed that the evidence in support of different BRATs in ACS undergoing PCI is influenced by ethnicity. Moreover, absolute risk reduction estimation revealed that some BRATs might be more effective than others in reducing bleeding according to ethnicity. CONCLUSION: The majority of BRATs are associated with reduced bleeding without any trade-off in hard ischaemic endpoints regardless of ethnicity. However, the supporting evidence and relative safety profiles of different BRATs might be significantly affected by ethnicity, which should be taken into account in clinical practice. STUDY REGISTRATION: This study is registered in PROSPERO (CRD42023416710).


Assuntos
Síndrome Coronariana Aguda , Inibidores da Agregação Plaquetária , Humanos , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/tratamento farmacológico , Etnicidade , Hemorragia/induzido quimicamente , Aspirina , Isquemia/tratamento farmacológico
6.
Expert Rev Cardiovasc Ther ; 21(12): 901-911, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37919937

RESUMO

INTRODUCTION: Bivalirudin, a bivalent direct thrombin inhibitor, has been developed to reduce bleeding without any trade-off in thrombotic events in acute coronary syndrome (ACS) patients undergoing percutaneous coronary intervention (PCI). AREAS COVERED: Despite showing a superior safety profile compared with unfractionated heparin (UFH), bivalirudin is not considered the anticoagulant of choice in ACS patients undergoing PCI, mainly because of an increased rate of acute stent thrombosis (ST) shown by several randomized controlled trials (RCTs), in addition to limited availability in certain countries and increased costs. However, RCTs on bivalirudin have been characterized by several confounding factors hindering the interpretation of its safety and efficacy compared with UFH among the spectrum of ACS patients. Furthermore, a significant body of evidence has demonstrated that the risk of acute ST can be mitigated by a full-dose infusion regimen following PCI, without compromising the favorable safety profile compared to UFH. EXPERT OPINION: In light of the increased understanding of the prognostic relevance of bleeding events and the excellent safety profile of bivalirudin, recent trial evidence may allow for this anticoagulant agent to reemerge and have a more prominent role in the management of ACS patients undergoing PCI.


Assuntos
Síndrome Coronariana Aguda , Intervenção Coronária Percutânea , Humanos , Síndrome Coronariana Aguda/tratamento farmacológico , Resultado do Tratamento , Hirudinas/efeitos adversos , Heparina/efeitos adversos , Antitrombinas/efeitos adversos , Anticoagulantes/efeitos adversos , Fragmentos de Peptídeos/efeitos adversos , Hemorragia/induzido quimicamente , Proteínas Recombinantes/efeitos adversos
7.
JACC Cardiovasc Interv ; 16(23): 2884-2896, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-37877914

RESUMO

BACKGROUND: There are no data comparing sirolimus-coated balloons (SCBs [MagicTouch, Concept Medical]) to paclitaxel-coated balloons (PCBs [SeQuent Please Neo, B. Braun]) for the treatment of de novo small vessel disease (SVD). OBJECTIVES: This study sought to compare quantitative coronary angiographic outcomes at 6 months after treatment of de novo SVD with a PCB or SCB. METHODS: This prospective, multicenter, noninferiority trial randomized 121 patients (129 SVD lesions) to treatment with an SCB or PCB, with balloon sizing determined using optical coherence tomography. The primary endpoint was noninferiority for the 6-month angiographic net lumen gain. RESULTS: Angiographic follow-up was completed in 109 (90.1%) patients in the per-protocol analysis. The mean ± SD angiographic net gains were 0.25 ± 0.40 mm with SCBs vs 0.48 ± 0.37 mm with PCBs, resulting in SCBs failing to meet the 0.30 mm criterion for noninferiority (Pnoninferiority = 0.173), with an absolute difference of -0.23 mm (95% CI: -0.37 to -0.09) secondary to a smaller late loss (0.00 ± 0.32 mm vs 0.32 ± 0.47 mm; P < 0.001) and more frequent late lumen enlargement (53.7% vs 30.0%; OR: 2.60; 95% CI: 1.22-5.67; P = 0.014) with PCBs. Binary restenosis rates were 32.8% and 12.5% following treatment with SCBs and PCBs, respectively (OR: 3.41; 95% CI: 1.36-9.44; P = 0.012). The mean angiography-derived fractional flow ratio at follow-up was 0.86 ± 0.15 following treatment with SCBs and 0.91 ± 0.09 following PCBs (P = 0.026); a fractional flow ratio ≤0.80 occurred in 13 and 5 vessels after treatment with SCBs and PCBs, respectively. CONCLUSIONS: The SCB MagicTouch failed to demonstrate noninferiority for angiographic net lumen gain at 6 months compared to the PCB SeQuent Please Neo.


Assuntos
Angioplastia Coronária com Balão , Paclitaxel , Sirolimo , Doenças Vasculares , Humanos , Materiais Revestidos Biocompatíveis , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Paclitaxel/uso terapêutico , Bifenilos Policlorados , Estudos Prospectivos , Sirolimo/uso terapêutico , Resultado do Tratamento , Doenças Vasculares/terapia
8.
Int J Cardiol ; 389: 131236, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37532153

RESUMO

BACKGROUND: Horizontal aorta (HA), defined by an aortic angulation (AA) ≥48°, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL). OBJECTIVES: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA. METHODS: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes. RESULTS: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing ≥ moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of ≥moderate PVL vs. Neo: (5% vs. 15%; p < 0.001), which was confirmed also at 90-day follow-up. Additionally, no correlation was found between ≥moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort. CONCLUSION: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of ≥moderate PVL, when compared with its predecessor.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Desenho de Prótese , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Sistema de Registros
9.
JACC Cardiovasc Interv ; 16(4): 396-411, 2023 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-36858659

RESUMO

BACKGROUND: The optimal access route in patients with severe peripheral artery disease (PAD) undergoing transcatheter aortic valve replacement (TAVR) remains undetermined. OBJECTIVES: This study sought to compare clinical outcomes with transfemoral access (TFA), transthoracic access (TTA), and nonthoracic transalternative access (TAA) in TAVR patients with severe PAD. METHODS: Patients with PAD and hostile femoral access (TFA impossible, or possible only after percutaneous treatment) undergoing TAVR at 28 international centers were included in this registry. The primary endpoint was the propensity-adjusted risk of 30-day major adverse events (MAE) defined as the composite of all-cause mortality, stroke/transient ischemic attack (TIA), or main access site-related Valve Academic Research Consortium 3 major vascular complications. Outcomes were also stratified according to the severity of PAD using a novel risk score (Hostile score). RESULTS: Among the 1,707 patients included in the registry, 518 (30.3%) underwent TAVR with TFA after percutaneous treatment, 642 (37.6%) with TTA, and 547 (32.0%) with TAA (mostly transaxillary). Compared with TTA, both TFA (adjusted HR: 0.58; 95% CI: 0.45-0.75) and TAA (adjusted HR: 0.60; 95% CI: 0.47-0.78) were associated with lower 30-day rates of MAE, driven by fewer access site-related complications. Composite risks at 1 year were also lower with TFA and TAA compared with TTA. TFA compared with TAA was associated with lower 1-year risk of stroke/TIA (adjusted HR: 0.49; 95% CI: 0.24-0.98), a finding confined to patients with low Hostile scores (Pinteraction = 0.049). CONCLUSIONS: Among patients with PAD undergoing TAVR, both TFA and TAA were associated with lower 30-day and 1-year rates of MAE compared with TTA, but 1-year stroke/TIA rates were higher with TAA compared with TFA.


Assuntos
Ataque Isquêmico Transitório , Doença Arterial Periférica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Resultado do Tratamento , Sistema de Registros
10.
Catheter Cardiovasc Interv ; 101(4): 798-805, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36841945

RESUMO

OBJECTIVES: The objective of this study is to investigate the use of cutting balloon (CB) inflated at high pressure compared with noncompliant balloon (NCB) for the treatment of calcified coronary lesions. BACKGROUND: No data are available regarding the safety and efficacy of CB inflated at high pressure in coronary artery calcifications. METHODS: Patients with calcified lesions (more than 100° of calcium demonstrated at baseline intravascular ultrasound) were randomized. Primary endpoint of the study was the final minimal stent area (MSA) and stent symmetry in the calcific segment. Secondary endpoints included rate of device failure and the 1-year rate of target lesion revascularization, target vessel revascularization, and major adverse cardiovascular events. RESULTS: From September 2019 to June 2021, a total of 100 patients were included and randomized; 13 patients were excluded for major protocol deviations. Lesions were complex (type B2/C n = 61 [71.2%]) with a mean arch of calcium of 266 ± 84°, a calcium length of 12 ± 6.6 mm. CB was inflated at comparable atmospheres when compared with NCB (18.3 ± 5 vs. 19 ± 4.5, p = 0.46). In the per-protocol population, the final MSA at the level of the calcium site was significantly higher in the CB group (8.1 ± 2 vs. 7.3 ± 2.1, p = 0.035) with a higher eccentricity index achieved in the CB group (0.84 ± 0.07 vs. 0.8 ± 0.08, p = 0.013). Three device failure occurred in the CB group. One-year follow-up outcomes were comparable. CONCLUSIONS: Treatment of calcified lesions with high-pressure CB has a good safety profile and is associated with a larger MSA and higher eccentricity of the stent at the level of the calcium site compared with NCB.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Humanos , Angiografia Coronária , Cálcio , Resultado do Tratamento , Doença da Artéria Coronariana/terapia , Stents
12.
J Invasive Cardiol ; 34(12): E884, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36476821

RESUMO

To the best of our knowledge, this is the first report of simultaneous grasping of the 3 leaflets during TriClip (Abbott Cardiovascular) implantation. The final valve configuration with a triple orifice resembled the result of the clover surgical technique. This technique should be considered in selected cases of challenging grasping.

13.
Front Cardiovasc Med ; 9: 977142, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36237898

RESUMO

Clinically significant tricuspid regurgitation (TR) is common and associated with excess mortality. At the same time right ventricular (RV) failure is a complex clinical syndrome that results from many causes, but is often associated with long-term prognosis. Whilst results of isolated tricuspid valve (TV) surgery are often unsatisfactory and limited by the prohibitive risk of most patients, the recent development of percutaneous recovery techniques has opened new scenarios. In consideration of the complexity of the mechanisms that lead to right heart failure and RV dysfunction it is important to understand the real advantages that percutaneous TV treatment can offer, more specifically the effect of TR reduction on RV remodeling in the setting of functional tricuspid regurgitation (fTR).

14.
JACC Cardiovasc Interv ; 15(15): 1543-1554, 2022 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-35926921

RESUMO

BACKGROUND: As transcatheter aortic valve (TAV) replacement is increasingly used in patients with longer life expectancy, a sizable proportion will require redo TAV replacement (TAVR). The unique configuration of balloon-expandable TAV (bTAV) vs a self-expanding TAV (sTAV) potentially affects TAV-in-TAV outcome. OBJECTIVES: The purpose of this study was to better inform prosthesis selection, TAV-in-TAV outcomes were assessed according to the type of initial and subsequent TAV. METHODS: Patients from the Redo-TAVR registry were analyzed using propensity weighting according to their initial valve type (bTAV [n = 115] vs sTAV [n = 106]) and subsequent valve type (bTAV [n = 130] vs sTAV [n = 91]). RESULTS: Patients with failed bTAVs presented later (vs sTAV) (4.9 ± 2.1 years vs 3.7 ± 2.3 years; P < 0.001), with smaller effective orifice area (1.0 ± 0.7 cm2 vs 1.3 ± 0.8 cm2; P = 0.018) and less frequent dominant regurgitation (16.2% vs 47.3%; P < 0.001). Mortality at 30 days was 2.3% (TAV-in-bTAV) vs 0% (TAV-in-sTAV) (P = 0.499) and 1.7% (bTAV-in-TAV) vs 1.0% (sTAV-in-TAV) (P = 0.612); procedural safety was 72.6% (TAV-in-bTAV) vs 71.2% (TAV-in-sTAV) (P = 0.817) and 73.2% (bTAV-in-TAV) vs 76.5% (sTAV-in-TAV) (P = 0.590). Device success was similar according to initial valve type but higher with subsequent sTAV vs bTAV (77.2% vs 64.3%; P = 0.045), primarily because of lower residual gradients (10.3 mm Hg [8.9-11.7 mm Hg] vs 15.2 mm Hg [13.2-17.1 mm Hg]; P < 0.001). Residual regurgitation (moderate or greater) was similar after bTAV-in-TAV and sTAV-in-TAV (5.7%) and nominally higher after TAV-in-bTAV (9.1%) vs TAV-in-sTAV (4.4%) (P = 0.176). CONCLUSIONS: In selected patients, no association was observed between TAV type and redo TAVR safety or mortality, yet subsequent sTAV was associated with higher device success because of lower redo gradients. These findings are preliminary, and more data are needed to guide valve choice for redo TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
16.
JACC Cardiovasc Interv ; 15(11): 1101-1110, 2022 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-35595675

RESUMO

BACKGROUND: The first-generation ACURATE neo transcatheter heart valve (THV) (Boston Scientific) was associated with a non-negligible occurrence of moderate or greater paravalvular aortic regurgitation (AR) following transcatheter aortic valve replacement. To overcome this issue, the ACURATE neo2 iteration, which incorporates a taller outer skirt aimed at reducing the occurrence of paravalvular AR, has recently been developed. OBJECTIVES: The aim of this study was to assess the efficacy and safety of the ACURATE neo2 (Boston Scientific) THV in patients with severe aortic valve stenosis. METHODS: ITAL-neo was an observational, retrospective, multicenter registry enrolling consecutive patients with severe aortic valve stenosis, treated with first- and second-generation ACURATE neo THVs, via transfemoral and trans-subclavian access, in 13 Italian centers. One-to-one propensity score matching was applied to account for baseline characteristics unbalance. The primary endpoint was the occurrence of moderate or greater paravalvular AR on predischarge echocardiographic assessment. Secondary endpoints included postprocedural technical success and 90-day device success and safety. RESULTS: Among 900 patients included in the registry, 220 received the ACURATE neo2 THV, whereas 680 were treated with the first-generation device. A total of 410 patients were compared after 1:1 propensity score matching. The ACURATE neo2 THV was associated with a 3-fold lower frequency of postprocedural moderate or greater paravalvular AR (11.2% vs 3.5%; P < 0.001). No other hemodynamic differences were observed. Postprocedural technical success was similar between the 2 cohorts. Fewer adverse events were observed in patients treated with the ACURATE neo2 at 90 days. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement using the ACURATE neo2 was associated with a significant lower frequency of moderate or greater paravalvular AR compared with the earlier generation ACURATE neo device, with encouraging short-term safety and efficacy.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Hemodinâmica , Humanos , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
17.
Eur J Cardiothorac Surg ; 61(4): 934-941, 2022 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-35188566

RESUMO

OBJECTIVES: Vascular complications (VC) are the most frequent drawback of transcatheter aortic valve implantation (TAVI), affecting up to 20% of overall procedures. Data on the treatment and their long-term impact are scarce. The goal of this study was to report on the incidence, management and impact on the long-term outcomes of VC following TAVI. METHODS: This was a multicentric retrospective analysis of consecutive patients undergoing TAVI. The primary endpoint was freedom from major adverse cardiac and cerebrovascular events at long-term follow-up. Adverse events were evaluated according to Valve Academic Research Consortium-2 criteria. RESULTS: A total of 2145 patients were included: VC occurred in 188 (8.8%); of which 180 were limited to the access site. Two-thirds of the VC were minor; 8% required surgical treatment; the remaining were repaired percutaneously. The major adverse cardiac and cerebrovascular events-free survival at 2 years was 83.0% for patients with VC and 86.7% for those without (P = 0.143), but 71.9% for patients with major compared to 89.0% in those with minor VC (P = 0.022). Major VC and diabetes mellitus independently predicted worse outcomes at 2 years. The major adverse cardiac and cerebrovascular events-free survival rate and the occurrence of vascular adverse events in the long term among patients with VC at the access site treated by endovascular techniques (covered stent implantation or angioplasty) were similar to those without VC (84.2% vs 86.7%; P = 0.635). CONCLUSIONS: Major but not minor VC impact long-term survival after TAVI. Covered stents implanted to manage VC at the access site have no impact on the long-term clinical outcome of TAVI.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
18.
J Am Coll Cardiol ; 77(18): 2263-2273, 2021 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-33958122

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPI) remains one of the main drawbacks of transcatheter aortic valve replacement (TAVR), but scarce data exist on PPI after valve-in-valve (ViV) TAVR, particularly with the use of newer-generation transcatheter heart valves (THVs). OBJECTIVES: The goal of this study was to determine the incidence, factors associated with, and clinical impact of PPI in a large series of ViV-TAVR procedures. METHODS: Data were obtained from the multicenter VIVID Registry and included the main baseline and procedural characteristics, in-hospital and late (median follow-up: 13 months [interquartile range: 3 to 41 months]) outcomes analyzed according to the need of periprocedural PPI. All THVs except CoreValve, Cribier-Edwards, Sapien, and Sapien XT were considered to be new-generation THVs. RESULTS: A total of 1,987 patients without prior PPI undergoing ViV-TAVR from 2007 to 2020 were included. Of these, 128 patients (6.4%) had PPI after TAVR, with a significant decrease in the incidence of PPI with the use of new-generation THVs (4.7% vs. 7.4%; p = 0.017), mainly related to a reduced PPI rate with the Evolut R/Pro versus CoreValve (3.7% vs. 9.0%; p = 0.002). There were no significant differences in PPI rates between newer-generation balloon- and self-expanding THVs (6.1% vs. 3.9%; p = 0.18). In the multivariable analysis, older age (odds ratio [OR]: 1.05 for each increase of 1 year; 95% confidence interval [CI]: 1.02 to 1.07; p = 0.001), larger THV size (OR: 1.10; 95% CI: 1.01 to 1.20; p = 0.02), and previous right bundle branch block (OR: 2.04; 95% CI: 1.00 to 4.17; p = 0.05) were associated with an increased risk of PPI. There were no differences in 30-day mortality between the PPI (4.7%) and no-PPI (2.7%) groups (p = 0.19), but PPI patients exhibited a trend toward higher mortality risk at follow-up (hazard ratio: 1.39; 95% CI: 1.02 to 1.91; p = 0.04; p = 0.08 after adjusting for age differences between groups). CONCLUSIONS: In a contemporary large series of ViV-TAVR patients, the rate of periprocedural PPI was relatively low, and its incidence decreased with the use of new-generation THV systems. PPI following ViV-TAVR was associated with a trend toward increased mortality at follow-up.


Assuntos
Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Implantação de Prótese , Sistema de Registros
19.
J Am Heart Assoc ; : e019236, 2021 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-33794658

RESUMO

Background Recurrence of mitral regurgitation (MR) after surgical mitral valve repair (SMVR) varies and may require reoperation. Redo mitral valve surgery can be technically challenging and is associated with increased risk of mortality and morbidity. We aimed to assess the feasibility and safety of MitraClip as a treatment strategy after failed SMVR and identify procedure modifications to overcome technical challenges. Methods and Results This international multicenter observational retrospective study collected information for all patients from 16 high-volume hospitals who were treated with MitraClip after failed SMVR from October 29, 2009, until August 1, 2017. Data were anonymously collected. Technical and device success were recorded per modified Mitral Valve Academic Research Consortium criteria. Overall, 104 consecutive patients were included. Median Society of Thoracic Surgeons score was 4.5% and median age was 73 years. At baseline, the majority of patients (82%) were in New York Heart Association class ≥III and MR was moderate or higher in 86% of patients. The cause of MR pre-SMVR was degenerative in 50%, functional in 35%, mixed in 8%, and missing/unknown in 8% of patients. The median time between SMVR and MitraClip was 5.3 (1.9-9.7) years. Technical and device success were 90% and 89%, respectively. Additional/modified imaging was applied in 21% of cases. An MR reduction of ≥1 grade was achieved in 94% of patients and residual MR was moderate or less in 90% of patients. In-hospital all-cause mortality was 2%, and 86% of patients were in New York Heart Association class ≤II. Conclusions MitraClip is a safe and less invasive treatment option for patients with recurrent MR after failed SMVR. Additional/modified imaging may help overcome technical challenges during leaflet grasping.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...